Ducted Inverter Split System
For complete home heating and cooling select a ducted split system. The Lennox DC Inverter Ducted Split System gives you the ability to zone your home according to your personal heating and cooling requirements. This means you can choose to heat or cool only the areas of your home that you will be using.
Energy efficient DC Inverter technology delivers superior temperature control. A variable speed drive in the motor system adjusts to match your air conditioning requirements. When you select your desired temperature, your Lennox ducted system will work at 100% capacity to deliver you comfort quickly. However, instead of switching off and on to maintain temperature, the variable speed drive activates and constantly varies the compressor speed to maintain the desired temperature with minimal fluctuations.
The result is that you’ll enjoy consistent temperature as well as significant savings and reduced running costs.
Key Features
-
Sleek Unobtrusive Design
Slim, discreet condenser design which doesn’t intrude on your outdoor space. -
Quiet Peaceful Operation
Quiet operation, allowing you to enjoy the comforts of your home, undisturbed by unwanted noise. -
Anti-corrosion Condenser Fins
The outdoor coil is treated to improve fin corrosion resistance and heat transfer for longer life and improved performance. -
Ease of Operation
Easy to operate, wall mounted LCD programmable thermostat control gives you the ultimate control of your indoor climate of your home.
Specifications
|
Model Number |
Indoor / Outdoor |
LED100V4 / LCD100V4 |
|
|
Performance |
COOLING |
HEATING |
|
|
Capacity |
kW |
10.5 |
11.0 |
|
(min - max) |
(4.2 - 12.0) |
(4.4 - 13.0) |
|
|
Input Power |
kW |
3.26 |
3.2 |
|
EER / COP* |
W/W |
3.18 |
3.386 |
|
Star Rating* |
1.5 |
2.0 |
|
|
Air Flow (H/M/L) |
Indoor (L/S) |
750 / 514 / 389 |
|
|
Outdoor (L/S) |
1389 |
||
|
Sound Level |
Indoor dB(A) |
54 - 48 |
|
|
Outdoor dB(A) |
62 |
||
|
Operating Range |
Indoor (oC) |
17 - 30 |
|
|
Outdoor (oC) |
-15 - 43 |
||
|
Electrical |
|||
|
Volts / HZ / Phase |
Indoor |
240 / 50 / 1 |
|
|
Outdoor |
240 / 50 / 1 |
||
|
Rated Running Capacity |
A |
14.9 |
14.6 |
|
Max Current |
Outdoor (A) |
22.0 |
|
|
Starting Current |
Outdoor (A) |
3.5 |
|
|
Interconnecting Wire |
mm2 |
3 core shielded wire (3 x 0.5) |
|
|
Installation |
|||
|
Unit Dimensions (W x H x D) |
Indoor (mm) |
1200 x 400 x 808 |
|
|
Outdoor (mm) |
990 x 966 x 354 |
||
|
Weight (Nett/Gross) |
Indoor (kg) |
71 / 77 |
|
|
Outdoor (kg) |
70 / 83 |
||
|
Spigot Connection Size |
Supply (mm) |
900 x 250 |
|
|
Return (mm) |
995 x 340 |
||
|
Refrigerant |
R410A (g) |
2750 |
|
|
Pre-charged Length |
M |
5 |
|
|
Max Pipe Run |
M |
30 |
|
|
Max Elevation |
M |
20 |
|
|
Pipe Sizes |
mm (inch") |
9.5 x 15.88 (3.8" & 5/8") |
|
|
Drain Pipe Connection |
mm |
OD32mm |
|
|
Moisture Removal |
L/h |
2.4 |
|
|
*When tested in accordance with AS/NZS 3823.2 |
|||